Cooling plating rectifier
ZY-Air cooling plating rectifier
ZY-Air cooling plating rectifier through the air cooled rectifier, it is divided into two control modes of steady flow/steady pressure. Customers can choose manual control mode /485RTU communication control mode/automatic control mode according to production requirements. After our company 20 years of technology accumulation and users' suggestions. Our company's rectifier design is very user-friendly.
Quantity:
ZY-Air cooling plating rectifier through the air cooled rectifier, it is divided into two control modes of steady flow/steady pressure. Customers can choose manual control mode /485RTU communication control mode/automatic control mode according to production requirements. After our company 20 years of technology accumulation and users' suggestions. Our company's rectifier design is very user-friendly.
| Parameters | Description |
| Voltage Regulation Precision | ≤0.5% |
| Current Stabilization Precision | ≤0.5% |
| ripple factor | ≤3% |
| Working Conditions | Indoor only |
| Evironments conditions | -10℃ ~ +45℃ |
| Level of Protection | IP20 |
| Type of Cooling | Air Cooling |
| Input | AC 3phase 380 & 2 p |
| Output | Voltage:0~12 V (adjustable) |
| Electricity:0~2000 Amp (adjustable) | |
| control Mode | RS485(RTU),autocontrol, semi-automatic |
•
Short circuit protection.
•
Under/ Over voltage protection.
•
Over temperature protection.
•
High quality of copper using.
•
With strong structure strength in PVC/ steel, attractive appearance
& strong corrosion resistance.
•
It has characteristics of low noise, less heat & high energy
efficiency.
•
We make this focus for using for copper plating, tin plating, nickel
plating & gold plating.
•
Phase lack protection
•
Input Over/ Low voltage protection
•
Working conditions from 10°C 45°C.
•
Suitable of automatic electroplating lines
Short circuit protection.
•
Under/ Over voltage protection.
•
Over temperature protection.
•
High quality of copper using.
•
With strong structure strength in PVC/ steel, attractive appearance
& strong corrosion resistance.
•
It has characteristics of low noise, less heat & high energy
efficiency.
•
We make this focus for using for copper plating, tin plating, nickel
plating & gold plating.
•
Phase lack protection
•
Input Over/ Low voltage protection
•
Working conditions from 10°C 45°C.
•
Suitable of automatic electroplating lines